Abstract
This report will focus on the sensitivity analysis of ordinary differential equation (ODE) models since they can be used to model so-called Low Frequency Oscillations (LFOs). LFOs are permanent complex valued voltage oscillations with a frequency of up to 2 Hz occurring in electrical systems like the European electrical transmission system. As an energy network is an “electro-mechanical system” with power produced and consumed by mechanical systems, Surmann et al. (2014) point out that a mechanical system of connected harmonic oscillators is suitable for modeling LFOs. Mathematically, this model is based on a system of ordinary differential equations.
Description
Table of contents
Keywords
sensitivity analysis, ordinary differential equation, low frequency oscillations