Testing for image symmetries – with application to confocal microscopy

dc.contributor.authorBissantz, Nicolai
dc.contributor.authorHolzmann, Hajo
dc.contributor.authorPawlak, Miroslaw
dc.date.accessioned2008-11-26T14:53:01Z
dc.date.available2008-11-26T14:53:01Z
dc.date.issued2008-11-26T14:53:01Z
dc.description.abstractStatistical tests are introduced for checking whether an image function f(x, y) defined on the unit disc D = {(x, y) : x2 + y2 ≤ 1} is invariant under certain symmetry transformations of D, given that discrete and noisy data are observed. We consider invariance under reflections or under rotations by rational angles, as well as joint invariance under both reflections and rotations. Furthermore, we propose a test for rotational invariance of f(x, y), i.e., for checking whether f(x, y), after transformation to polar coordinates, only depends on the radius and not on the angle. These symmetry relations can be naturally expressed as restrictions for the Zernike moments of the image function f(x, y), i.e., the Fourier coefficients with respect to the Zernike orthogonal basis. Therefore, our test statistics are based on checking whether the estimated Zernike coefficients approximately satisfy those restrictions. This is carried out by forming the L2 distance between the image function and its transformed version obtained by some symmetry transformation. We derive the asymptotic distribution of the test statistics under both the hypothesis of symmetry as well as under fixed alternatives. Furthermore, we investigate the quality of the asymptotic approximations via simulation studies. The usefulness our theory is verified by examining an important problem in confocal microscopy, i.e., we investigate possible imprecise alignments in the optical path of the microscope. For optical systems with rotational symmetry, the theoretical point-spread-function (PSF) is reflection symmetric with respect to two orthogonal axes, and rotationally invariant if the detector plane matches the optical plane of the microscope. We use our tests to investigate whether the required symmetries can indeed be detected in the empirical PSF.en
dc.identifier.urihttp://hdl.handle.net/2003/25881
dc.identifier.urihttp://dx.doi.org/10.17877/DE290R-14256
dc.language.isoende
dc.subjectImage symmetryen
dc.subjectNanoscale bioimagingen
dc.subjectNonparametric estimationen
dc.subjectPoint-spread-functionen
dc.subjectSymmetry detectionen
dc.subjectZernike momenten
dc.subject.ddc004
dc.titleTesting for image symmetries – with application to confocal microscopyen
dc.typeTextde
dc.type.publicationtypereporten
dcterms.accessRightsopen access

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
tr18-08-Bissantz.pdf
Size:
622.27 KB
Format:
Adobe Portable Document Format
Description:
DNB
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.92 KB
Format:
Item-specific license agreed upon to submission
Description: