Authors: | Tantimongcolwat, Tanawut Isarankura-Na-Ayudhya, Chartchalerm Srisarin, Apapan Galla, Hans-Joachim Prachayasittikul, Virapong |
Title: | Polyacrylamide hydrogel encapsulated E. coli expressing metal-sensing green fluorescent protein as a potential tool for copper ion determination |
Language (ISO): | en |
Abstract: | A simple, inexpensive and field applicable metal determination system would be a powerful tool for the efficient control of metal ion contamination in various sources e.g. drinking-water, water reservoir and waste discharges. In this study, we developed a cell-based metal sensor for specific and real-time detection of copper ions. E. coli expressing metal-sensing green fluorescent protein (designated as TG1/(CG)6GFP and TG1/H6CdBP4GFP) were constructed and served as a metal analytical system. Copper ions were found to exert a fluorescence quenching effect, while zinc and cadmium ions caused minor fluorescence enhancement in the engineered bacterial suspension. To construct a user-friendly and reagentless metal detection system, TG1/H6CdBP4GFP and TG1/(CG)6GFP were encapsulated in polyacrylamide hydrogels that were subsequently immobilized on an optical fiber equipped with a fluorescence detection module. The sensor could be applied to measure metal ions by simply dipping the encapsulated bacteria into a metal solution and monitoring fluorescence changes in real time as a function of the metal concentration in solution. The sensor system demonstrated high specificity toward copper ions. The fluorescence intensities of the encapsulated TG1/(CG)6GFP and TG1/H6CdBP4GFP were quenched by approximately 70 % and 80 % by a high-dose of copper ions (50mM), respectively. The level of fluorescence quenching exhibited a direct correlation with the copper concentration, with a linear correlation coefficient (r) of 0.99. The cell-based metal sensor was able to efficiently monitor copper concentrations ranging between 5 µM and 50 mM, encompassing the maximum allowed copper contamination in drinking water (31.15 µM) established by the WHO. Furthermore, the cell-based metal sensor could undergo prolonged storage for at least 2 weeks without significantly influencing the copper sensitivity. |
Subject Headings: | green fluorescent protein metal sensor copper optical sensor |
URI: | http://hdl.handle.net/2003/33528 http://dx.doi.org/10.17877/DE290R-15513 |
Issue Date: | 2014-04-07 |
Appears in Collections: | Original Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Prachayasittikul_07042014_proof.pdf | DNB | 812.9 kB | Adobe PDF | View/Open |
This item is protected by original copyright |
If no CC-License is given, pleas contact the the creator, if you want to use thre resource other than only read it.