dc.description.abstractThe degradation rate of magnesium (Mg) alloys is a key parameter to develop Mg-based biomaterials and ensure in vivo-mechanical stability as well as to minimize hydrogen gas production, which otherwise can lead to adverse effects in clinical applications. However, in vitro and in vivo results of the same material often differ largely. In the present study, a dynamic test bench with several single bioreactor cells was constructed to measure the volume of hydrogen gas which evolves during magnesium degradation to indicate the degradation rate in vivo. Degradation medium comparable with human blood plasma was used to simulate body fluids. The media was pumped through the different bioreactor cells under a constant flow rate and 37 °C to simulate physiological conditions. A total of three different Mg groups were successively tested: Mg WE43, and two different WE43 plasma electrolytically oxidized (PEO) variants. The results were compared with other methods to detect magnesium degradation (pH, potentiodynamic polarization (PDP), cytocompatibility, SEM (scanning electron microscopy)). The non-ceramized specimens showed the highest degradation rates and vast standard deviations. In contrast, the two PEO samples demonstrated reduced degradation rates with diminished standard deviation. The pH values showed above-average constant levels between 7.4–7.7, likely due to the constant exchange of the fluids. SEM revealed severe cracks on the surface of WE43 after degradation, whereas the ceramized surfaces showed significantly decreased signs of corrosion. PDP results confirmed the improved corrosion resistance of both PEO samples. While WE43 showed slight toxicity in vitro, satisfactory cytocompatibility was achieved for the PEO test samples. In summary, the dynamic test bench constructed in this study enables reliable and simple measurement of Mg degradation to simulate the in vivo environment. Furthermore, PEO treatment of magnesium is a promising method to adjust magnesium degradation.en
dc.identifier.urihttp://hdl.handle.net/2003/38544
dc.identifier.urihttp://dx.doi.org/10.17877/DE290R-20463
dc.language.isoende
dc.relation.ispartofseriesInt. J. Mol. Sci.;20(19)
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectBioreactoren
dc.subjectMagnesiumen
dc.subjectDegradationen
dc.subjectPlasma electrolytic oxidation (PEO)en
dc.subject.ddc660
dc.subject.rswkBioreaktorde
dc.subject.rswkMagnesiumde
dc.subject.rswkBiologischer Abbaude
dc.subject.rswkElektrochemische Oxidationde
dc.titleIn vivo simulation of magnesium degradability using a new fluid dynamic bench testing approachen
dc.typeTextde
dc.type.publicationtypearticlede
dcterms.accessRightsopen access
eldorado.secondarypublicationtruede
eldorado.secondarypublication.primarycitationJung, O.; Porchetta, D.; Schroeder, M.-L.; Klein, M.; Wegner, N.; Walther, F.; Feyerabend, F.; Barbeck, M.; Kopp, A. In Vivo Simulation of Magnesium Degradability Using a New Fluid Dynamic Bench Testing Approach. Int. J. Mol. Sci. 2019, 20, 4859.de
eldorado.secondarypublication.primaryidentifierhttps://doi.org/10.3390/ijms20194859de

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ijms-20-04859.pdf
Size:
3.08 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.85 KB
Format:
Item-specific license agreed upon to submission
Description: