Autor(en): Schuler, Julia
Herath, Jakob
Kockmann, Norbert
Titel: X‐ray‐based tomographic imaging for the investigation of laminar mixing in capillaries
Sprache (ISO): en
Zusammenfassung: Micro-computed tomography is a promising non-invasive imaging technology that offers high spatial resolution without requiring optical access. This opens the opportunity to analyze concentration fields in mixing equipment in 3D. To demonstrate the potential of the methodology, laminar mixing in helically coiled capillaries is investigated by tracking the radial distribution of potassium iodide along the main flow direction. Dean flow can be observed in the helically coiled capillaries, which intensifies with Reynolds number and decreasing effect of gravity.
Schlagwörter: Dean flow
Helically coiled capillary
Micro-computed tomography
Three-dimensional concentration fields
URI: http://hdl.handle.net/2003/42328
http://dx.doi.org/10.17877/DE290R-24165
Erscheinungsdatum: 2022-05-06
Rechte (Link): https://creativecommons.org/licenses/by/4.0/
Enthalten in den Sammlungen:Arbeitsgruppe Apparatedesign



Diese Ressource ist urheberrechtlich geschützt.



Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons